Pre-use adjustment of rotary cultivator

1, level adjustment. Remove the cultivator from the ground and check whether the height of the knife tip at the left and right ends is the same as the height of the blade. You can adjust it with the right lifting lever.

2, before and after horizontal adjustment. First, the rotary tiller is lowered to the required tillage depth, and the length of the upper adjustment rod (central railing) is changed so that the intermediate transmission gearbox is in a horizontal state (or the central transmission output shaft is parallel).

3, to enhance the height adjustment. The gimbal is not inclined more than 30 degrees when it rises. In general, the tip of the knife can be turned and freed only about 20 centimeters from the ground. When working in the field, the maximum lifting position should be limited.

4, the adjustment of the performance of broken soil. Under normal circumstances, use the speed of change to adjust the performance of the soil. However, a rotary cultivator with an intermediate transmission box can also be adjusted by changing the spindle speed.

5, the adjustment of cultivation. When the unit and the tractor with powerful adjustment and position adjustment hydraulic system are used for rotary tillage operation, the position adjustment shall be used, and the use of force adjustment shall be prohibited so as not to damage the rotary tiller. After the rotary tiller reaches the required tillage depth, apply a limit screw to block the position adjustment handle so that each tillage depth is consistent.

Isolation clothes, also known as clean work clothes, clean work clothes, purification clothes, dust-free clothes, sterile clothes, anti-static work clothes, dust-free work clothes, work clothes, protective clothes, etc.
In addition to the fact that clothing itself cannot be a source of dust emission, it also has the effect of preventing dust from being emitted by the human body. At the same time, as a sterile clothing, it should have basic properties such as safety protection, comfort, ease of operation, aesthetics, etc. in materials and design. Otherwise, due to the different styles, fabrics and sterile underwear of the work clothes, it directly affects the number of dust and colonies in the clean room.
Widely used in electronic, pharmaceutical, food, biological engineering, optics, aerospace, aviation, color tube, semiconductor, precision machinery, plastics, paint spray, hospitals, environmental protection and other industry clean workshops, there are a variety of colors and specifications suitable for different anti-static Or clean environment.
* Performance editing
100% high-density polyethylene material, one-piece hooded design, breathable and moisture-permeable, can block the penetration of fine dust and liquids, and at the same time allow water vapor to permeate; light and tough, prevent the accumulation of static electricity, it does not produce dust , Free of silicon.
It is made of special polyester filament, warp or warp and weft inlaid with Japanese bell spinning 9R series conductive fiber, and manufactured by a special process. Has excellent, long-lasting conductivity. It is a necessary measure for anti-static of personnel clothing.
The charge of work clothes: <0.6 micro library / piece. Charge area density: <7 microbanks / square meter.
(Annotation of "micro-coulomb": "coulomb" is a unit of charge measurement, 1 coulomb = 1000 milli-coulomb = 1,000,000 micro-coulomb. 6.25 × 108 electrons carry 1 coulomb, and the power of one electron belt is 1.6 × 10 19 coulombs).
* Fabric editing
The fabrics used are: fabrics containing conductive silk, gabardine, yarn cards, TYVEK (acid and alkali resistance), etc.
Conventional optional fabrics: 5mm strip type, 5mm mesh, 2.5mm mesh fabric conductive silk, its anti-dust and anti-static effect is getting stronger and stronger in order; this is also selected according to the clean room level, generally CLASS10000 The clean room below (ten thousand area) should use 5mm strip conductive silk, CLASS1000 (thousand level area) and 5mm grid should be used; CLASS100 (100 level area) clean room should use 2.5mm grid fabric conductive silk.
Isolation clothing fabric-like characteristics
1. Japanese original parallel wire processing technology, with excellent anti-static performance, is permanent and can effectively discharge human body electrostatic charge;
2. The clothing itself is not dusty, non-sticky, has good barrier properties, high density, high strength, can effectively sterilize, and inhibit bacteria
3. Good washing resistance, bending resistance, abrasion resistance, etc., washing resistance ≥100 times, high temperature steam temperature: 120 ℃;
4. All-over-seaming process of special equipment imported from Japan, one-time forming, good dust resistance, can be used in 10-10 thousand grade clean room;
5. Especially recommend the production and sales of breathable anti-static clean clothes.
* Advantage edit
1. The fabric itself does not produce dust: because it is worn in a clean room, the fabric must not be a source of dust in the clean room, which determines that ultra-clean fabrics can only be produced with chemically synthesized long fibers. Natural short fibers such as cotton, hemp, and silk cannot be applied to ultra-clean fabrics, although these raw materials can make the fabrics more wearable. At the same time, it is required that the selected chemical fiber filaments also strictly control the amount of dust generated. Generally speaking, fully matt polyester filament is not suitable for weaving anti-static ultra-clean fabrics. Because the matting agent added in the production of polyester-titanium dioxide will become a source of pollution.
2. The fabric should have good dust filter: the dust in the clean room mainly comes from the air flowing in the room and the human body moving in the room. When the equipment conditions are determined, improving the cleanliness means that the fine dust generated by the human body should be controlled in the clothes to the maximum, and let it pass through the fabric and enter the air. This is the so-called fabric filter rate is higher. Increasing the dust filtration rate is at the expense of the breathability of the fabric, so knitted fabrics and woven fabrics that are more loosely woven are not suitable for clean rooms.
* Edit specifications
The fabrics used are: fabrics containing conductive silk, gabardine, yarn cards, TYVEK (acid and alkali resistance), etc.
Conventional optional fabrics: 5mm strip type, 5mm mesh, 2.5mm mesh fabric conductive silk, its anti-dust and anti-static effect is getting stronger and stronger in order; this is also selected according to the clean room level, generally CLASS10000 The clean room below (ten thousand area) should use 5mm strip conductive silk, CLASS1000 (thousand level area) and 5mm grid should be used; CLASS100 (100 level area) clean room should use 2.5mm grid fabric conductive silk.

Isolation Gown

Disposable Isolation Clothing,Disposable Isolation Gown,Disposable Medical Isolation Gown,Disposable Hospital Isolation Gown

Guangzhou Aikangli Medical Technology Co., Ltd. , https://www.aikanli.com