YYD series digital display plant stem strength detector instruction manual

YYD series digital display plant stem strength detector instruction manual
Thank you for choosing the products and services of Zhejiang Top Instrument Co., Ltd.
Please read the instruction manual carefully before using the product.
First , the functional characteristics
The YYD series digital plant stem strength tester is a key factor in determining the lodging resistance of crops. The lodging of plants such as corn, sorghum and tobacco poses great difficulties for the mechanical harvesting of crops. Cause a lot of waste. In addition, the lodging of crops leads to insufficient illumination, which limits their production. The stalks are measured in vivo at various stages of crop growth, and the population measurement data are statistically processed according to the correlation between the bending resistance and the lodging resistance of the stalk fiber layer, which is of great significance for crop cultivation and breeding.
Second, the functional characteristics
1, high precision and high resolution.
2. It has the characteristics of simple operation, full function and convenient carrying.
3. Pressure (Kpa) and pressure (N) are available for selection and conversion.
4, with a backlight function. (Without the operation of the display button, no backlight is displayed after 10 seconds)
5, with green environmental protection, automatic shutdown function. (The display will automatically shut down after 10 minutes without the operation of the display button)
Third, technical parameters
1. Model: YYD-1A, YYD-1B.
2. Maximum load: 50 N for YYD-1A and 500 N for YYD-1B.
3. Resolution: YYD-1A type 0.01 N, YYD-1B type 0.1N.
4. Measuring stem diameter: 0 to 40 mm.
5. Measurement accuracy: ±0.5%.
6, unit: Kpa, N.
7, operating temperature: -10 ° C ~ +60 ° C;
8, Dimensions: length 295mm × width 130mm × thickness 36mm
9, net weight: ~600g
Note: YYD-1A is designed to measure wheat, rice, etc.; YYD-1B is used to measure corn, sugar cane, sorghum and so on.
Fourth, the product schematic
1, the trademark 2, the button
3, liquid crystal display 4, accessories (probe)
Fifth, the display panel

Top Instrument
Welcome your use
Six, the button description
1, open key: can be used to boot and shut down.
2, unit key: can be used to convert units, pressure (Kpa) and pressure (N).
3. Pressure button: displays the current measured pressure or pressure value.
4, save button
a. Press this button in the measurement state to save the current measured pressure (including pressure), time, and storage serial number.
b. Press this button in the query state to view the next record.
c. Press this button in the time adjustment state to save the currently set date and time.
d. Press this button in the auto save setting state to save the current set auto save time.
5, clear the key
a. Press this button in the measurement state to clear the current measured force value. After the instrument is cleared, the interval should be 3 seconds before the next measurement .
b. Press this button in the query state to clear the currently stored measured force value.
c. Press and hold this button in the query state to delete all stored records.
d. Press this button in the system menu state to cycle through the menus (including: time setting, auto save setting).
e. Press this button in the auto save setting state to set the auto save time (00~60 minutes). When it is set to 00, it will turn off the auto save function.
f. Press this button in the time setting state to adjust the current time values.
6, the query key
a. Press this button in the measurement state to view the last record.
b. Press this button in the query state to view the previous record.
c. Press this button in the welcome interface to enter the system menu.
d. Press this button in the system menu state to enter the current menu item.
e. Press this button in the time setting state to set the year, month, day, hour and minute respectively.
Seven, user instructions
1, boot display

Top Instrument
Welcome your use
Boot display factory information and welcome to use:
User main interface display

Peak value: 0000.00Kpa
Pressure: 0000.00 Kpa

2, using the system menu interface

Press the ON/KEY button to display the welcome screen. Press the Query button to display the following:

System menu
â–ºTime setting
Full scale setting
Auto save settings
The setting item is selected by the clear key, and when the setting item of the user is selected, the parameter setting interface is accessed by pressing the inquiry key.
3, parameter setting interface
In the user settings interface, press the Query key to enter the parameter setting interface as shown below:
a, time setting

time setting
â–º2010, 13:00
January 54 minutes
03th
The setting item is selected by the clear key, and the data is modified by the inquiry key. At this time, press the save key to confirm that the saving is successful. (Time setting range: 00:00 on 01 January 2010 to 23:59 on December 31, 2030, minimum time value is 1 minute)
★ b , full scale setting: Users are not allowed to use this setting.
c, automatically save settings

Auto save settings
00 minutes
The data is modified by the query key. At this time, press the save key to confirm that the save is successful. (Set the time for automatic saving (00 to 60 minutes). When set to 00, it means to turn off the automatic saving function.)
Eight, test operation steps
1, the digital plant stem strength tester before use:
a. Select the appropriate accessories (Attachment 1 applies to the erect crop stems and Annex 2 applies to crops that have torn rice stripe disease). As shown below:

Annex 1 Annex 2

b. Connect the selected accessory (probe) to the host.
c. Press the power button to turn on the power.
2. Fix the stem with rubber strip and attachment and place it at a height of 20cm from the ground. Pay attention to the direction of the ear when measuring, as shown below:

ground
3. At this height, the stem pushes the crop at right angles until the crop is at an angle of 45 degrees to the ground, as shown in the image above.
4. Record the pressure value and note the number of stems.
Nine, attention, maintenance and repair
1. When the power button is not displayed, it indicates that the battery has no power and needs to be replaced.
2. Do not tap the LCD to place the object on the LCD.
3. Do not press the function keys with nails, sharp objects or sharp objects.
4. Handle and handle gently during use and handling.
5. Do not disassemble, repair or modify the unit yourself. These behaviors can cause permanent malfunction of the instrument.
6. If the fault occurs, please contact the original purchase office or the company.
7. This product has a product quality problem within one month from the date of sale, in the normal use and appearance without damage, the customer with the original sales invoice, valid warranty card and complete packaging to the original purchase or the company to replace the same specifications For the model, the replacement product will continue the warranty period and terms of the original product.
8. This product is within one year from the date of sale. Under normal use, non-human failure is covered by the warranty (users disassemble or repair the company at other repair points and the warranty), the customer with the original sales invoice and valid warranty If you contact the original purchase office, you can get a free warranty for one year.
9. The warranty terms of this product are only applicable to the YYD series products sold in the Chinese market. For products that exceed the replacement period and warranty period, the customer can inquire the original purchase office for repairs or contact the company, and the company provides paid repairs. .
Other supporting instruments :
equipment name
model
equipment name
model
Soil nutrient speedometer
TPY-6A
Crop nutrition diagnostic apparatus
ZYY-1
Soil moisture meter
TZS-I
Photosynthetically active radiometer
(photon quantum meter)
GLZ-A
TZS
GLZ-B
TZS-II
GLZ-C
Soil moisture temperature measuring instrument
TZS-IW
Agriculture and forest microclimate collection system
(Field Environment Recorder)
NL-5
TZS-W
Temperature and humidity light three parameter recorder
DJL-18
TZS-IIW
Handheld agricultural environment monitor
TNHY-4
Soil moisture temperature recorder
TZS-IX
TNHY-6
Soil moisture temperature recorder
TZS-2X
TNHY-7
Soil moisture temperature recorder
TZS-3X
TNHY-9
Pen soil moisture meter
BS-30
TNHY-11
BS-40
Temperature and humidity loggers
TPJ-20
Soil hardness tester
TYD-1
Temperature illuminance recorder
TPJ-22
Digital soil hardness tester
TYD-2
Carbon dioxide recorder
TPJ-26
Soil compaction meter
TJSD-750
Wind direction wind speed recorder
TPJ-30
TJSD-750-II
Rainfall recorder
TPJ-32
Chlorophyll meter
TYS-A
Fruit hardness tester
GY-3
TYS-B
GY-4
Living leaf area measuring instrument
YMJ-A
Fruit sugar meter
TD-45
YMJ-B
Automatic Kjeldahl
ZDDN-II

Disposable Face Mask

Disposable Face Mask,Children Face Mask,3 Ply Face Mask,Ear-Loop Face Mask

Suzhou Xuanweicheng Biotechnology Co., Ltd , https://www.xwc-medical.com